SIMODRIVE611轴卡P095参数改不了
问题补充:
SIMODRIVE611A的,轴卡6SN1121-0BA11-0AA1
钻石用户推荐最佳答案
参数需要打开写保护,具体流程如下:
1.Power–up?the?unit―――(supply?ON)
2.Does?the?operating?display”P–000”?appear?yes往下no跳到7.步(有报警的解决报警)
3.?Set?P–051?to?4H(remove?write?protection?打开写保护
4.?Set?P–097?to?0H(start?initialization)初始化
5.?Set?P–052?to?1H(write?into?FEPROM?写入FEPROM?
6.?Wait?until?P–052?is?again?set?to?0H,then?switch?the?converter?off?and?2?s?after?the?operating?display?has?been?canceled,?power–up?again?等待2秒52自动变为0H?断电重启
7. 更改P-095
8 参考3-6步保存更改参数
提问者对于答案的评价: