SITRANS LR250 FEA 全密封防护天线雷达. What chemicals are not suited for use with the TFM TM 1600 PTFE lens material? 天线防护面的材质TFM1600 PTFE 不适合应用于那些腐蚀性化学介质?

问题:
What chemicals are not suited for use with the TFM TM 1600 PTFE lens material?
天线防护面的材质TFM1600 PTFE 不适合应用于那些腐蚀性化学介质?

解答:
Generic PTFE is compatible with approximately 99% of materials found in industry where the SITRANS LR250 Flanged Encapsulated Antea is used.
Some chemicals not recommended for use with PTFE are;

  • Flourine based chemicals – PTFE is a fluorine based material.

  • Diethylamine.二乙胺

  • Gold Monocyanide

Note: These are guidelines only and care must be taken with chemical compatibility. Compatibility information can be widely found on the Internet.

SITRAN LR250 PTFE全密封防护天线雷达主要应用领域中的99%的介质都是PTFE可以抵御的。
有少数一些介质不建议用PTFE天线。

  • 含氟的化学物质-FTFE本身基于氟制成

  • 二乙胺

  • 氰化亚金

注意:这些仅为大概指导,具体工况需要全方面考虑介质与天线材质的化学兼容性。网上可以找到大量关于物质之间化学兼容性的信息。