小弟调试机床840DSL 系统 时侯,一定要在WINSCP中执行 SC disable s_cycles, 才可以让机床启动。请问,这句指令有啥作用啊?? 还有就是WINSCP 中类似的这种指令在哪可以查到啊??
最佳答案
NCU的升级文件中摘录:
The "programGUIDE" (earlier, cycle support) in SINUMERIK Operate 2.6 SP1 is based on these cycle packages
2.6. Cycle calls in the part programs for these cycles cannot be re-compiled and processed with the cycle
support in HMI-Advanced 7.x. This also means that the simulation function in HMI-Advanced cannot be used. If
the cycle support of HMI-Advanced 7.x is to be used, then the cycle packages 7.x contained in HMI-Advanced -
should be downloaded into the NC after deactivating the cycles 2.6 with the service command "sc disable
s_cycles". This means that no SINUMERIK Operate operation is permissible.
就是说若用PCU50.3装了hmi advance,而你又非用hmi advance的程序模拟就需要装在pcu自带的循环和定义,而这就会和NCU中cf中自带的循环冲突,所以必须关闭NCU的循环。若用NCU或PCU上装的operate界面,你千万不能运行SC disable s_cycles,否则循环都无法使用。
提问者对于答案的评价:
谢谢
原创文章,作者:more0621,如若转载,请注明出处:https://www.zhaoplc.com/plc212338.html