S120通过starter设置,关于控制字

我单位是200t起重机,其主钩S120逆变控制字如图1,第十位置1了,表示用PLC进行控制,可是我们起重机上没有PLC啊,我问了好多人,都不知道,求助各位。我把参数也附上。
Control structure:
   Control type: [21] Speed control (with encoder)
Power unit:
   Component name: Motor_Module_2
   Component type: Single motor module
   Order no.: 6SL3320-1TE41-0AAx
   Rated power: 560 kW
   Rated current: 985 A
Power unit supplementary data:
   No filter/choke
Drive setting:
   Standard: IEC motor (50Hz, SI units)
   Connection voltage: 560 V
   Power unit application: [0] Load duty cycle with high overload for vector drives
Motor:
   Motor name: Motor_5
   Motor type: [1] Induction motor (rotating)
Motor data:
   p304[0]: Rated motor voltage 380 Vrms
   p305[0]: Rated motor current 538.00 Arms
   p307[0]: Rated motor power 280.00 kW
   p308[0]: Rated motor power factor 0.860
   p310[0]: Rated motor frequency 50.00 Hz
   p311[0]: Rated motor speed 742.0 rpm
   p335[0]: Motor cooling type [1] Forced cooling
Optional Motor Data:
   p320[0]: Motor rated magnetizing current/short-circuit current 219.071 Arms
   p322[0]: Maximum motor speed 0.0 rpm
   p341[0]: Motor moment of inertia 11.548091 kgm2
   p342[0]: Ratio between the total and motor moment of inertia 5.016
   p344[0]: Motor weight (for the thermal motor model) 2100.0 kg
   p352[0]: Cable resistance 0.00483 ohm
   p353[0]: Motor series inductance 0.000 mH
Equivalent Circuit Diagram Data:
   p350[0]: Motor stator resistance cold 0.00765 ohm
   p354[0]: Motor rotor resistance cold / damping resistance d axis 0.00253 ohm
   p356[0]: Motor stator leakage inductance 0.12856 mH
   p358[0]: Motor rotor leakage inductance / damping inductance d axis 0.13438 mH
   p360[0]: Motor magnetizing inductance/magn. inductance d axis saturated 2.93983 mH
Calculation of the Motor/Controller Data:
   No calculation
Motor holding brake:
   Motor holding brake: [3] Motor holding brake like sequence control connection via BICO
   Extended brake control
   Brake control module type: [0] Brake control with diagnostics evaluation
Encoder:
   Encoder evaluation name 1: SM_3
   Name Encoder 1: Encoder_4
   Encoder type Encoder 1: User-defined
   Order no. encoder 1: XExxxxx-xxxxx-xxxx
Drive functions:
   Technological application: [0] Standard drive (VECTOR)
   Motor identification: [0] Inhibited
Process data exchange (drive):
   PROFIdrive telegram: [999] Free telegram configuration with BICO
Important parameters:
   Current limit: 807.00 Arms
   Minimum speed: 0.000 rpm
   Maximum speed: 750.000 rpm
   Ramp-up time: 3.000 s
   Ramp-down time: 3.000 s
   Ramp-down time w. OFF 3 3.000 s

图片说明:

S120通过starter设置,关于控制字    S120通过starter设置,关于控制字    S120通过starter设置,关于控制字   

最佳答案

通过第一张图可以看出你的控制方式为i端子启停,,P854的工厂默认值就是1,你的启动以及使能都为端子,而且需要DP通讯的时候,在通讯里面还要设置相应的报文,输入输出的数据长度,,这些你都没有设置,所以说854的值是不是为1没有意义,,

提问者对于答案的评价:
要想端子控制必须P854位置1,PLC控制是连接第一个控制字的bit10,我现在明白了,谢谢你们的回答